There are some commercial HVAC problems that announce themselves immediately. A system stops working, occupants complain, and the service call is underway. A refrigerant leak can be much less obvious.

At first, the only clue might be that a building isn’t cooling as effectively as it used to. Perhaps an air-conditioning system runs longer than normal, an office feels warmer than usual, or energy costs begin creeping upward. These symptoms can have many possible causes, which is why refrigerant leak detection requires more than simply looking for a puddle beneath the equipment.

Refrigerant is contained within a closed HVAC system, so a loss of refrigerant generally indicates that something is wrong with the system. Leaks can develop in coils, fittings, connections, piping, or other components. Finding the source is essential because simply adding refrigerant doesn’t correct the underlying problem.

Tri-Tech Energy provides commercial HVAC services throughout New Jersey and has nearly 40 years of experience working with commercial heating and cooling systems. In this article, we’ll look at the common signs of a refrigerant leak, what can cause one, and some of the methods HVAC technicians use to locate leaks.

What Does Refrigerant Do in a Commercial HVAC System?

Refrigerant is a substance used within the refrigeration cycle to absorb and release heat. In an air-conditioning system, refrigerant changes between liquid and vapor as it moves through various components. It absorbs heat from indoor air and ultimately allows that heat to be rejected outside the building.

The refrigerant itself isn’t supposed to disappear during normal operation. A properly functioning closed system should maintain its refrigerant charge. That means a system that is losing refrigerant has a problem that needs to be identified.

What Are the Signs of a Refrigerant Leak?

A refrigerant leak isn’t always immediately apparent. Some of the most common symptoms can overlap with other HVAC problems, which is why professional diagnosis is important.

1. Reduced Cooling Performance

One of the most noticeable signs of a refrigerant leak is declining cooling performance.

A commercial air-conditioning system may continue running, but the building doesn’t reach the desired temperature as efficiently as it once did. Occupants may notice that certain spaces are warmer than expected.

2. Longer Cooling Cycles

If an HVAC system has difficulty reaching its setpoint, it may operate for extended periods. Longer run times can increase energy consumption and put additional strain on equipment.

3. Ice on Coils or Refrigerant Lines

Ice or frost on components of an air-conditioning system can sometimes indicate low refrigerant levels. However, restricted airflow and other mechanical issues can produce similar symptoms.

That’s why seeing ice doesn’t automatically confirm a refrigerant leak.

4. Unusual Hissing or Bubbling Sounds

Depending on the location and size of a leak, escaping refrigerant can sometimes produce unusual sounds. A technician may listen for these clues when inspecting equipment.

5. Increasing Energy Costs

A system struggling to provide adequate cooling may have to operate longer and harder. If energy consumption increases without a corresponding change in building use, it may be worth investigating the HVAC system.

What Causes Commercial HVAC Refrigerant Leaks?

There isn’t one universal cause. Refrigerant leaks can develop for several reasons.

Corrosion

Coils and other components can deteriorate over time, particularly in demanding commercial environments. Corrosion may eventually create small openings through which refrigerant escapes.

Vibration

Commercial HVAC equipment contains moving components. Over time, vibration can place stress on connections, joints, and piping.

Damaged Components

Physical damage to coils, lines, or other HVAC components can create a pathway for refrigerant to escape.

Aging Equipment

As HVAC equipment gets older, seals, fittings, coils, and other components may become more susceptible to deterioration.

Installation or Connection Problems

Improperly secured connections can potentially lead to leaks. Quality installation and commissioning are important parts of maintaining a reliable commercial HVAC system.

How to Detect a Refrigerant Leak

So, how do you detect a refrigerant leak when there isn’t an obvious visual sign?

HVAC technicians have several methods available. The appropriate method depends on the equipment, the suspected location of the leak, and other factors.

Electronic Leak Detectors

Electronic detection equipment can identify refrigerant concentrations in the air around HVAC components. These tools can be particularly useful when dealing with small leaks that aren’t immediately visible.

Soap Solution Testing

A technician may apply an approved leak-detection solution to suspected areas. If refrigerant is escaping, bubbles can indicate the location of the leak.

Pressure Testing

Pressure testing can help technicians evaluate whether a system is holding pressure appropriately and assist in locating leaks within the system.

Visual Inspection

A thorough visual inspection is still an important part of the process. Technicians can examine coils, fittings, connections, piping, and other components for signs of damage or deterioration.

Combining Detection Methods

Finding a leak isn’t always a one-tool job. A technician may use multiple diagnostic methods to pinpoint a difficult-to-find leak and determine the appropriate repair.

What Happens After a Refrigerant Leak Is Found?

Finding the leak is only the beginning. The next step is determining whether the affected component can be repaired or needs to be replaced. The technician must also evaluate the overall condition of the HVAC equipment and determine why the leak occurred in the first place.

Simply adding refrigerant without addressing the source can allow the problem to return. A professional evaluation can help determine the appropriate repair strategy and whether the equipment remains a practical candidate for continued service.

For older commercial HVAC systems, a recurring commercial HVAC refrigerant leak may also be a reason to consider whether continued repairs make financial sense compared with equipment replacement or a larger system upgrade.

Don’t Ignore the Warning Signs

A commercial HVAC system doesn’t have to completely stop working before it deserves attention. Declining cooling performance, longer operating cycles, unexplained energy increases, or unusual equipment behavior can all warrant an inspection.

Refrigerant leaks can be particularly frustrating because their symptoms can resemble other HVAC problems. That’s why proper refrigerant leak detection is so important. Identifying the actual cause allows building owners and facility managers to make informed decisions about repairs, maintenance, or replacement.

Think your commercial HVAC system may have a refrigerant leak? Contact Tri-Tech Energy for professional service and troubleshooting or visit our website: https://www.tritechenergy.com/